| Purpose |
ESD-protected work area |
A dissipative work surface connected to a verified common ground |
It controls the discharge of static electricity so sensitive electronic devices are not exposed to sudden electrostatic energy. |
Use only ESD-control materials within the protected area. |
| Ergonomics |
Work-surface height |
Approximately 700–750 mm for seated work |
This range supports a neutral working posture for many seated operators while leaving adequate space for equipment and wiring. |
Adjust the height when possible; keep wrists and shoulders relaxed. |
| Ergonomics |
Work-surface depth |
Approximately 750–900 mm |
The depth provides room for the operator, ESD mat, instruments, and assemblies without placing frequently used items outside the comfortable reach zone. |
Keep heavy instruments stable and close to the rear of the bench. |
| Ergonomics |
Work-surface width |
Approximately 1,200–1,800 mm |
The width allows separation between the device under assembly, test instruments, documentation, and material storage. |
Avoid overcrowding the protected work area. |
| Grounding |
Common point ground |
One designated grounding point for the work surface and personnel grounding equipment |
A common point ground reduces voltage differences between conductive and dissipative items that the operator may touch. |
Do not create unauthorized ground connections or use an unverified electrical outlet ground. |
| Grounding |
Grounding conductor |
Dedicated protective conductor connected to the facility grounding system |
The conductor provides a controlled path for dissipating charge from the bench and connected ESD accessories. |
Inspect terminals, plugs, and cables for looseness, cuts, or corrosion. |
| Work surface |
Dissipative bench mat |
Surface resistance commonly specified in the dissipative range: 1 × 106 to less than 1 × 109 Ω |
The mat allows charge to drain gradually rather than producing a rapid spark discharge. |
Keep the mat clean, undamaged, and connected to the common point ground. |
| Personnel grounding |
Wrist strap system |
Adjustable band with a current-limiting resistor, commonly 1 MΩ |
The wrist strap places the operator at the same electrical potential as the grounded work surface while limiting current for safety. |
Test the strap before use and wear it in direct contact with the skin. |
| Personnel grounding |
ESD footwear and floor system |
Used where wrist straps are impractical or when standing work is required |
Conductive or dissipative footwear and flooring provide a controlled path from the operator to ground. |
Use the approved footwear-and-floor combination; ordinary shoes may interrupt the path. |
| Verification |
Wrist-strap test |
Perform before entry or before starting work, according to the site procedure |
The tester checks continuity and the resistance of the current-limiting path. |
Stop work and replace or repair the system if the test fails. |
| Verification |
Mat-to-ground test |
Verify the mat-to-ground resistance using a calibrated surface-resistance or ground-monitoring instrument |
The test confirms that the mat has a continuous, controlled path to the designated ground. |
Record results at the interval defined by the ESD control plan. |
| Air control |
Relative humidity |
Common operating target: 30–70% RH |
Moderate humidity generally reduces charge generation and improves charge dissipation compared with very dry conditions. |
Humidity control supports, but does not replace, grounding and ESD-safe materials. |
| Air ionization |
Ionizer |
Used when insulating materials or isolated conductors cannot be grounded |
Balanced positive and negative ions neutralize electrostatic charge on isolated objects and surfaces. |
Check ionizer balance and discharge time at the specified distance and maintenance interval. |
| Ionizer verification |
Typical performance checks |
Offset voltage often evaluated against a ±35 V criterion; decay time is application-dependent |
Offset voltage indicates ion balance, while decay time indicates how quickly the ionizer removes charge from a test plate. |
Use the limits defined by the facility’s ESD program and the equipment specification. |
| Material handling |
ESD-sensitive devices |
Keep devices inside shielding packaging until they are within the protected area |
Shielding packaging limits the electric field and electrostatic discharge reaching the device during transport and storage. |
Ground the operator before opening protective packaging. |
| Material handling |
Insulating materials |
Keep unnecessary plastics, foam, paper, and synthetic fabrics away from exposed devices |
Insulators can retain charge and may transfer it through contact or induce charge on nearby conductors. |
Use approved ESD-safe alternatives or neutralize unavoidable insulators with ionization. |
| Layout |
Protected work zone |
All exposed ESD-sensitive items should remain within the grounded or ionized area |
The protected zone ensures that devices, tools, containers, and the operator remain at controlled electrical potentials. |
Mark the boundary clearly and keep the area free of non-ESD items. |
| Tools |
Hand tools and test equipment |
Use grounded, dissipative, or ESD-rated tools where required |
Tool surfaces and electrical connections can otherwise become charged and discharge into a component. |
Inspect tool insulation, grounding leads, tips, and calibration status. |
| Operating sequence |
Start-of-shift procedure |
Check ground connection, test personnel grounding, inspect the mat, and confirm the work area is clean |
A repeatable sequence identifies failures before sensitive devices are exposed to the workstation. |
Document failed checks and do not process sensitive hardware until corrected. |
| Maintenance |
Cleaning |
Use an ESD-compatible cleaner and lint-free materials as specified by the site procedure |
Contamination can increase surface resistance, reduce charge dissipation, and interfere with reliable electrical contact. |
Do not use unapproved cleaners, waxes, or silicone-based products. |
| Safety |
Electrical and mechanical safety |
Separate ESD grounding from protective-earth requirements unless the approved design combines them |
ESD control manages static charge, while protective grounding and circuit protection address electric-shock and equipment hazards. |
Keep cables organized, maintain clear access, and use qualified personnel for electrical changes. |
| Standards basis |
ESD control program |
Align procedures with the applicable edition of IEC 61340-5-1 and relevant local requirements |
A documented program defines technical limits, verification methods, training, records, and corrective actions. |
Use the current controlled copy of the applicable standard and site procedure. |